At a glance

HerringboneChevron
The blockRectangle, square ends: length L by width WParallelogram: long edge, width W, cut angle θ
How the ends meetEnd meets the side of the next block at 90°End meets end, point to point: a V of 2θ
HandingNone for square-edged blocks; tongue and groove blocks come handed (one supplier)Left- and right-hand blocks, in equal numbers
Line to build fromControl line and working lines, 45° diagonals (NWFA); column edge steppedThe spine: every V point on it; column edge straight
Repeat across / step along (90 x 450 block)636 mm / 127 mm45°: 636 / 127 mm; 60°: 779 / 104 mm

Distances: our arithmetic for a 90 x 450 mm block (chevron long edge 450 mm). Naming follows the pattern atlas.

Two rules, one block

The parquet pattern atlas names the patterns and sets out the convention used here: the cut angle θ is the acute angle between the end cut and the long edge, and the V between two chevron blocks is 2θ. This sheet does not repeat it. It asks what the choice does to the set-out.

Herringbone has square ends. Each block's end meets the side of the next, so every column is a zigzag with a stepped, saw-toothed edge. The straight line an installer builds from is a control line, with working lines either side and 45° diagonals (NWFA, Ornamental Floors, page 13 and Installation Guidelines, Chapter 7). Chevron has angled ends, so left- and right-hand blocks meet on a straight spine and every V point sits on it. The column edge is straight too. That straight spine is why a chevron floor reads as cleaner, and why one block set a hair off the spine shows at once.

Two things follow before any room is drawn. The reference lines are different, and a chevron block comes in two hands, so the order has to say how many of each.

Herringbone and chevron: the rule behind eachTwo patches of block flooring in plan. Left, herringbone: square-ended blocks, the end of each meeting the side of the next at a right angle, in a zigzag column. Right, chevron cut at 60 degrees: angled ends meeting on a straight spine in a V of 120 degrees. One block is picked out in green in each patch.HerringboneChevron, 60 degree cutends square: end meets side at 90°ends angled: end meets end in a V of 120°stepped edge to each zigzag columnstraight spine: every V point on one line
Herringbone and a 60 degree chevron in plan, one block picked out in each. Same block width and length. Original drawing by Make Bespoke Studio.

At 45 degrees, the same lattice

At 45° the two patterns are cousins. Take a herringbone block, cut the green triangle off one end and add it to the other, and you have a 45° chevron block: the same long edge, the same area and the same width. Because the block is only sheared, the lattice does not change. Turned so the columns run up the page, herringbone repeats every √2 × L across the columns and every √2 × W along them, and a 45° chevron of the same size repeats at exactly the same distances. That is why one supplier says a 45° chevron can look like herringbone.

The 60° cut changes both distances: a longer repeat across the room (779 mm instead of 636) and a shorter step along the spine (104 mm instead of 127). One supplier's guide says 60° is generally the more popular chevron cut but harder to fit.

For a 90 x 450 mm blockHerringboneChevron, 45° cutChevron, 60° cut
Area laid per block40,500 mm²40,500 mm²40,500 mm²
Repeat across the columns, P√2 × L = 636 mm2 × long edge × sin θ = 636 mm2 × long edge × sin θ = 779 mm
Step along a column, p√2 × W = 127 mmW ÷ sin θ = 127 mmW ÷ sin θ = 104 mm
Length of one block, tip to tip450 mm (square ends)long edge + W = 540 mmlong edge + W ÷ tan θ = 502 mm

Our arithmetic from the geometry above, not catalogue data. Replace W and the long edge with your own.

Common mistake: ordering from the wrong length. A maker may quote a chevron block tip to tip. Treat 540 mm as the long edge of the 45° block and you work out 20.6 blocks to the square metre instead of 24.7, which is 17% short (10% short at 60°, where the tip to tip length is 502 mm). Put the long edge, not the tip to tip length, on the drawing, and ask the workshop for its coverage per pack for the cut you specify.

A 45 degree chevron block is a herringbone block with its ends shearedA rectangle of length L and width W with a right-angled triangle of side W at its left end picked out. An arrow leads to a parallelogram of the same long edge L and the same area, with that triangle moved to the right end; its tip to tip length is L plus W. A panel at the right gives the repeat distances for a 90 by 450 block.Herringbone block, L by WLcut the green triangle off one endand add it to the other endlong edge Ltip to tip L + WSame block, same repeat90 x 450 mm, 45 degree cutArea per block40,500 mm²Across the columns, P636 mmAlong a column, p127 mmChevron tip to tip540 mmthe same for both blocks
A 45 degree chevron block is a herringbone block with its ends sheared: same long edge, same width, same area. Original construction by Make Bespoke Studio.

Set-out: crown line, repeat and the wall

Every guide we read sets the floor out from the centre, not from a wall. NWFA asks for a centre layout with working lines, a dry-laid small section to confirm the layout is balanced, and one row at a time with alignment checked as you go. One UK supplier calls the first two rows the crown line: they must be laid perfectly in line, left to cure (it says 24 hours) and only then built from, because a crown line that is out gives ever-increasing gaps as the floor is laid.

The step the guides skip is arithmetic. The pattern repeats at a fixed distance, so a room of any width puts each wall somewhere in that repeat. For a room 4,000 mm between expansion gaps with the crown line on the centre:

Room 4,000 mm wide, crown line on the centreHerringbone, 90 x 450Chevron 60°, 90 x 450
Pattern lines every (half the repeat)318 mm390 mm
Lines that fit each side of the crown line6, the last at 1,909 mm5, the last at 1,949 mm
The wall then falls beyond the last line by91 mm51 mm
What that leaves at each wallA cut band about one block wideA sliver narrower than a block
Fix 1: whole repeats for the field, frame or apron takes the rest6 repeats = 3,818 mm, rest 91 mm each side; or 5 repeats, 409 mm each side5 repeats = 3,897 mm, rest 51 mm each side; or 4 repeats, 441 mm each side
Fix 2: a block length that divides the room (if the workshop can cut it)L = 471 mm gives 6 repeatsLong edge 462 mm gives 5 repeats

NWFA gives the principle: adjust the apron (the band between the border and the wall) so cuts are equal on all sides, and let the field end with a whole or a half repeat of the pattern. A UK installer's article says the same of out-of-square walls: set the lines true and let the cut at the wall vary by a few millimetres, because a pattern that follows the wall drifts. On our room, a wall 10 mm out of true over 4 m turns a 51 mm sliver into 61 mm along its length; a pattern that followed it would carry 10 mm of drift to the far end.

Doorways. The installer's article ties the pattern to the most important doorway, and one supplier puts a chevron crown line on the centre of a doorway or other vista. Then check the phase. A 900 mm opening centred on the crown line has its jambs 132 mm past a pattern line in herringbone and 60 mm past one in 60° chevron, which is a thin cut piece at each jamb. How the floor then carries on past the threshold is a junction detail: see floor transitions and movement joints.

Set-out across a room: crown line, repeat and the sliver at each wallPlan of a room 4,000 millimetres wide, broken top and bottom. A 60 degree chevron floor of 90 by 450 millimetre blocks is centred on a crown line. Pattern lines fall every 390 millimetres, so the walls fall 51 millimetres beyond the last pattern line and the outer row is cut to a thin sliver. A key explains the crown line, the repeat, the sliver and the fix.crown line4,000 mm between expansion gapsrepeat 779sliver 51 at each wallReading the plan1Crown line: first tworows, cured beforethe rest is laid2Repeat across theroom: 779 mm at60 degrees3Each wall falls 51 mmpast a pattern line, sothe cut pieces (green)are slivers4Fix: whole repeats forthe field; a frame orapron takes the rest
A 60 degree chevron of 90 x 450 mm blocks across a room 4,000 mm between expansion gaps, centred on the crown line. Pieces cut at the walls are shown in green. Original drawing by Make Bespoke Studio, to scale across the room.

Where each goes wrong

Almost every fault traces to the start or to a number nobody wrote down. Each row below says which pattern it bites, how it shows, and what to ask for.

What goes wrongHow it showsHow to control it
Crown line out (both)Every row carries the error: gaps widen as the floor is laid (supplier).Two rows only, checked with a chalk line or laser, cured before the rest. Re-check every few rows (NWFA: one row at a time, alignment checked periodically).
Block width varies (both)NWFA: the length should be an exact multiple of the width, or the ends separate. One supplier states ±1.5% on dimensions: on a 90 mm block that is 1.35 mm, and ten steps along a column then drift about 19 mm.Ask for the width tolerance, de-select blocks outside it, and measure from the working lines instead of trusting the rows.
Cut angle off (chevron)A cut 0.5° out moves the tenth V along the spine by about 5 mm at 60° and 11 mm at 45°.Check the angle on the approved sample, and ask the tolerance on it.
Wrong hand mix (chevron)Short of one hand, a column cannot be finished.Order equal numbers of left and right, check the packs on delivery, and draw from several packs while laying.
Ordered from the wrong length (chevron)10% to 17% short on blocks (see above).Long edge on the drawing, coverage from the workshop for the cut.
Subfloor not flat (both)A pattern that runs out opens gaps; every inconsistency shows at the chevron points (our guides).NWFA gives about 1/8 in over 10 ft (3.2 mm over 3.05 m) for herringbone, UK suppliers 3 mm under a 2 m straight edge. Agree one test: subfloor requirements.
Walls and doorways ignored (both)Slivers at the walls; a thin piece at a jamb.Set out from the crown line and a hero doorway, use a frame or apron to take the difference, and draw it.

Drift figures are our arithmetic from the geometry and the cited tolerance. Tolerances, handing and cut angles are the partner workshop's to confirm.

What goes on the layout drawing

The layout drawing does the work the installer would otherwise improvise.

  • Pattern and block. Width, length and thickness. For chevron, the cut angle and how it is measured, and which length is quoted (long edge or tip to tip).
  • Hands. Equal numbers of left and right for chevron; handing for tongue and groove herringbone.
  • Direction. NWFA: the points may look best toward the longest dimension of the room or toward a major focal point. One maker suggests toward the main window. Choose and draw it.
  • Crown line. Its position, dimensioned from two fixed references, and the hero doorway it is tied to.
  • The edge. Frame or apron width, and how the field ends against it: whole repeat, half repeat, or a cut band of a stated minimum.
  • Doorways and thresholds. Where the pattern stops or carries on, and the strip.
  • Movement. Where the expansion gaps fall and what covers them.
  • Approval. A dry-laid sample area on site, signed off before fixing.

Quantities. One supplier's guide asks for at least 5% waste, and more for herringbone and chevron. In our own trial of a 4 x 6 m room and a 90 x 450 block, with no offcut reused, the cut-off came to about 9% to 23% depending on the pattern and where it started, so draw the layout before you pick a percentage.

Specification wording

Paste into your schedule or specification and replace anything in [square brackets] with your own figures. Wording is a starting point: your specification governs.

Layout drawing
Pattern: [herringbone / chevron] to layout drawing [ref]. Block [90] x [450] x [14] mm; for chevron, end cut [60] degrees measured between the end cut and the long edge, and [450] mm is the long edge, not tip to tip. Crown line on [the centre line of the room / the centre of doorway ref], dimensioned from [two fixed references]. Points face [the longest dimension of the room / the window wall]. Frame or apron [ ] mm wide takes up the irregularity of the walls; cuts at the walls to be equal on opposite sides.
Block tolerance and hands
Block width tolerance [+/- 0.2] mm and length tolerance [+/- 0.5] mm, stated by the workshop; blocks outside tolerance de-selected before laying. Chevron blocks supplied in equal numbers of left- and right-hand [and tongue and groove blocks handed], drawn from at least [three] packs while laying.
Start and checks
Crown line of two rows laid first, checked with [a chalk line / a laser], and left to cure for [24] hours before the rest is laid. Alignment re-checked every [ ] rows against the working lines; no row adjusted to follow a wall.
Quantities and approval
Quantity [ ] m2 calculated by the workshop from layout drawing [ref] for the cut specified, with an allowance of [ ] %. A sample area of [2 x 2] m dry-laid on site and approved by [the designer] before fixing.

Terms used on this page

Herringbone
A pattern of rectangular blocks laid so the end of each block meets the side of the next at a right angle, forming a zigzag of staggered rows.
Chevron
A pattern in which the ends of the blocks are cut at an angle so that neighbouring blocks meet point to point, forming a continuous V rather than a stepped zigzag.
Crown line
The first two rows, laid exactly on the set-out line and left to cure before the rest is built from them. One UK supplier's term; NWFA speaks of a control line with working lines either side.
Repeat (pattern)
The distance after which the pattern starts again; across the columns it is 636 mm for a 90 x 450 mm herringbone (our arithmetic).

All flooring terms

Standards and sources

  • NWFA Technical Publication No. B300, Ornamental Floors: Design & Installation (3rd edition, 2015): read: layout, working lines, herringbone, aprons.
  • NWFA Installation Guidelines, Section III, Chapter 7, Parquet Installation (revised 02.2016): read: herringbone layout.
  • A UK distributor's guidelines (Jan 2024), two UK supplier guides (2015, 2018): read: crown line, sizes, tolerance, handed blocks.
  • BS 8201:2011, BS EN 13226, 13227, 13489: named; not read. Check current editions.

Questions we are asked

What is the difference between herringbone and chevron?

In herringbone the blocks have square ends, and the end of each meets the side of the next at 90 degrees, so each column zigzags and its edge is stepped. In chevron the ends are cut at an angle and the blocks meet point to point on a straight spine in a V. Chevron blocks come as left- and right-hand pairs.

Is a 45 degree chevron the same as herringbone?

No, but it is built on the same lattice. A 45 degree chevron block is a herringbone block with its ends sheared: the same long edge, width and area. The repeat distances are identical, which is why the two can look alike. The ends and the column edge differ.

Which is harder to lay?

One UK supplier says 60 degree chevron is generally the more popular chevron cut but harder to fit, and our own wood flooring guide says every inconsistency in chevron shows at the points. Both patterns need a flat subfloor, a straight crown line and an experienced floor layer.

What is a crown line?

The first two rows of the floor, laid exactly on the set-out line and left to cure before the rest is built from them. A crown line that is out carries its error into every row.

Which way should the points face?

NWFA says herringbone may look best with the points toward the longest dimension of the room or toward a major focal point. One maker suggests toward the main light. There is no rule: choose it, and draw it.

Why do chevron floors end in slivers at the walls?

The pattern repeats at a fixed distance, so a wall can fall just past a pattern line and leave a thin cut piece. In our worked example, a 60 degree chevron of 90 x 450 mm blocks in a room 4,000 mm wide leaves 51 mm at each wall. Moving the repeat with a frame or apron, or a different block length, avoids it.

How much extra should I order?

A supplier's guide asks for at least 5% and more for herringbone and chevron. Our trial of a 4 x 6 m room gave about 9% to 23% cut-off without reusing offcuts. Ask the workshop to calculate the quantity from the layout drawing for the cut you specify.

Download the factsheet

A two-page A4 PDF with the comparison table, the set-out drawing and layout drawing wording, to keep with your project file.

Factsheet TL-FLO-14 v1.0 (PDF)